6. Disconnect the vacuum actuator pushrod from the mode valve lever and remove the actuator.
INSTALLATION PROCEDURE
1. Connect the vacuum actuator push rod from the mode valve lever and position the actuator.
2. Carefully rotate the mode vacuum actuator towards the rear of the vehicle until the actuator is engaged on the mounting pins on the HVAC
module.