Monte Carlo V6-3.4L VIN E (2000)
1. Position the temperature valve electric actuator, then align the slots in the electric actuator driver to the flats on the temperature valve shaft.
2. Slide the electric actuator driver onto the shaft, while aligning the actuator locating hole to the forward alignment pin on the HVAC module case.
The actuator driver should completely seat onto the temperature valve shaft and the mounting holes should be flush with the mounting bosses on
the HVAC module case.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the mounting bolts to the temperature actuator.
Tighten
Tighten the temperature actuator bolts to 1.5 N.m (13 lb in).
4. Connect the electrical connector to the temperature actuator.
5. Install the knee bolster.
6. Install the left instrument panel insulator.
Temperature Actuator Replacement (RH)
REMOVAL PROCEDURE
1. Remove the right side instrument panel insulator.
2. Remove the instrument panel compartment.
3. Disconnect the electrical connector from the temperature actuator.