A/C REFRIGERANT PRESSURE SENSOR REPLACEMENT
REMOVAL PROCEDURE
1. Disconnect the battery negative cable.
2. Remove the air cleaner and duct assembly.
3. Disconnect the electrical connector (2) from the A/C refrigerant pressure sensor.
4. Remove the A/C refrigerant pressure sensor (1) from the liquid line.
INSTALLATION PROCEDURE
1. Lubricate a new O-ring seal with mineral base 525 viscosity refrigerant oil.
2. Install the new O-ring seal.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the A/C refrigerant pressure sensor (1) to the liquid line.
Tighten
Tighten the A/C refrigerant pressure sensor to 4.7 N.m (41 lb in).
4. Connect the electrical connector (2) to the A/C refrigerant pressure sensor.
5. Install the air cleaner and duct assembly.
6. Connect the battery negative cable.