REMOVAL PROCEDURE
1. Remove the instrument panel cluster trim plate bezel.
2. Remove the screws from the headlamp switch housing.
3. Remove the headlamp switch housing from the instrument panel.
4. Disconnect the electrical connector from the headlamp switch.
5. Remove the headlamp switch from the headlamp switch housing.
INSTALLATION PROCEDURE
1. Install the headlamp switch to the headlamp switch housing, pressing into place until fully seated.
2. Connect the electrical connector to the headlamp switch.
3. Install the headlamp switch housing to the instrument panel.
4. Install the headlamp switch housing screws.
Tighten
Tighten the headlamp housing switch screws to 2 Nm (18 lb in).