9. Install the transaxle oil cooler pipe into the quick connect fitting.

10. Insert the transaxle oil cooler pipe end into the quick connect fitting until a click is either heard or felt.

11. Do not use the plastic cap on the transaxle oil cooler pipe in order to install the transaxle oil cooler pipe into the fitting.
12. Pull back sharply on the transaxle oil cooler pipe in order to ensure that the transaxle oil cooler pipe is fastened into the quick connect fitting.

13. Position (snap) the plastic cap onto the fitting. Do not manually depress the retaining ring when installing the plastic cap onto the quick connect

fitting.

14. Ensure that the plastic cap is fully seated against the fitting.