Monte Carlo V6-3.8L VIN K (1998)
Hydraulic Control Assembly - Antilock Brakes: Service and Repair
Modulator Gear Cover Replacement (B)
REMOVAL PROCEDURE
1. Remove the Torx head screws (4) that attach the gear cover (3).
2. Remove the gear cover (3).
INSTALLATION PROCEDURE
1. Install the gear cover (3) onto the modulator/master cylinder assembly.
2. Install the Torx head screws (4).
^
Tighten the Torx screws to 4 Nm (35 inch lbs.).
NOTICE: Refer to Fastener Notice in Cautions and Notices.