Use care when removing tube.

8. O-rings.

Install or Connect

1. New O-ring seals coated with mineral base 525 viscosity refrigerant oil.
2. Suction line into place.
3. Suction line at block fitting bolt.

Tighten
^

Bolt to 16 N.m (12 lb. ft.).

4. Suction line fitting at accumulator.

Tighten
^

Fitting to 47 N.m (35 lb. ft.).

5. Suction line bracket at strut tower.

Tighten
^

Nut to 3.3 N.m (29 lb. in.).

6. Liquid line/suction line bracket.
7. Evacuate, recharge, and leak test system. 
8. Air cleaner and duct assembly. 