Backup Lamp: Testing and Inspection
Circuit Operation

Voltage is applied at all times through the R/CMPT REL Fuse in the engine wiring harness junction block 1 to the transaxle range switch through circuit
840. When the transaxle is shifted into REVERSE, voltage is applied through the closed contacts of the transaxle range switch, to the RH and LH backup
lamps through circuit 24 The backup lamps are grounded through circuit 350 to G302.