chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Sensors and Switches - Emission Control Systems > < Positive Crankcase Ventilation Valve|Locations|Page 5350
Page 1
background image

Positive Crankcase Ventilation Valve: Service and Repair

REMOVAL PROCEDURE

1. Remove the injector sight shield from the fuel rail and intake. Refer to Engine Cover Replacement See: Engine, Cooling and

Exhaust/Engine/Service and Repair.

2. Remove the MAP sensor (1).
3. Use a 16 mm socket to press the access cover (2) down and rotate 1/4 turn counterclockwise.
4. Remove the access cover.
5. Remove the PCV valve (3) and the O-ring (4) from the intake manifold.

INSTALLATION PROCEDURE

1. Install the crankcase ventilation valve; replace the O-ring if necessary.
2. Install the access cover.
3. Install the MAP sensor.
4. Install the sight shield. Refer to Engine Cover Replacement See: Engine, Cooling and Exhaust/Engine/Service and Repair.

Sensors and Switches - Emission Control Systems > < Positive Crankcase Ventilation Valve|Locations|Page 5350