Monte Carlo V8-305 5.0L VIN G 4-bbl HP (1988)
Governor: Service and Repair
Turbo Hydra-Matic 4L60 (700-R4)
1.
Raise and support vehicle.
2.
Remove governor cover from case using extreme care not to damage cover. If cover is damaged, it must be replaced.
3.
Remove governor.
4.
Reverse procedure to install and check fluid level.