chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Housing Assembly HVAC|Description and Operation|Page 7185 > < Housing Assembly HVAC|Description and Operation
Page 2
background image

Air Distributor Duct

SYSTEM DESCRIPTION

Control of airflow through the HVAC module is regulated by vacuum-actuated doors. Outside air is either cooled or heated and then discharged
according to control setting. In case of vacuum line harness leakage or hose collapse, it is not necessary to replace the entire vacuum harness assembly.
Replacement can be made by cutting the hose and inserting a plastic connector. If an entire hose must be replaced, cut the hose off at the connector and
then attach a new hose directly to the vacuum solenoid control assembly.

VACUUM SYSTEM

All air valves except the temperature valve are controlled by engine vacuum stored in the vacuum tank in the engine compartment. The vacuum is routed
by a vacuum switch in the control assembly to any of the spring-loaded two or three-position vacuum actuators. One vacuum actuator is linked to each
air valve.

The vacuum switch in the control assembly is controlled by the mode lever or control knob. For each mode lever or control knob position, the vacuum

Housing Assembly HVAC|Description and Operation|Page 7185 > < Housing Assembly HVAC|Description and Operation