chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

All Technical Service Bulletins for Instrument Cluster / Carrier:|468304 > < Instrument Panel - Upper Surface Reflection
Page 1
background image

Instrument Cluster / Carrier: All Technical Service Bulletins
Temperature Gauge - Erratic

File In Section: 8 - Chassis/Body Electrical
 
Bulletin No.: 46-83-06

Date: December, 1994

Subject:
Erratic Temperature Gauge (Exchange Instrument Panel Cluster)

Models:
1994 Chevrolet and GMC Truck S/T Models
with Standard Analog Instrument Panel Cluster

Condition

Some temperature gauges in the above vehicles may give erratic readings.

Cause

Improper nut on back of temperature gauge inside the I/P cluster, resulting in erratic voltage feed to gauge.

Correction

Remove the instrument cluster and send it to your nearest Delco Repair Station. Repair stations are aware of the condition and have pans available to
repair the cluster. They will add a capacitor to the power circuit to assure a consistent power flow to the temperature gauge. Be certain to clearly describe
the condition on the Delco Repair Order accompanying the cluster.

Warranty Information

For vehicles repaired under warranty.

All Technical Service Bulletins for Instrument Cluster / Carrier:|468304 > < Instrument Panel - Upper Surface Reflection