chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 432 > < Diagram Information and Instructions|Page 430
Page 1
background image

Clutch Switch: Diagnostic Aids

Ohmmeter

An ohmmeter can be used instead of a self-powered test lamp. The ohmmeter shows how much resistance there is between two points along a circuit.
Low resistance means good continuity.

Circuits which include any solid state control modules, such as the Powertrain Control Module (PCM), should be tested only with a 10-megohm or
higher impedance digital multimeter (J 34029-A, J 39200, or equivalent).

When measuring resistance with a digital multimeter, the vehicle battery should be disconnected. This will prevent incorrect readings.

Diodes and solid state components in a circuit can cause an ohmmeter to give a false reading. To find out if a component is affecting a measurement, 
take a reading once, reverse the leads, then take a second reading. If the readings differ, the solid state component is affecting the measurement.

Fused Jumper Wire

A fused jumper is available (J 36169 or equivalent) with small clamp connectors providing adoption to most connectors without damage. This fused
jumper wire is supplied with a 20 amp fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects
the circuit being tested.

NOTICE:  Do not use fused jumper wire in any instance to substitute for inputs or outputs at the Powertrain Control Module (PCM) or any
microprocessor device.

Short Finder

Short Finders are available (J 8681-A or equivalent) to locate hidden shorts to ground. The short finder creates a pulsing magnetic field in the shorted
circuit and shows you the location of the short through body trim or sheet metal.

Fuse Tester

A simple tester that indicates a blown fuse is available (J 34764 or equivalent). To check a fuse, the tester is applied directly to the fuse in the fuse block.
Two probes contact the fuse. The probes are either placed into the slots of a flat fuse or to the metal ends of a glass fuse. With power on, a red LED in be
tester lights if the fuse is open. The handle of the tester is a tool for removing either type of fuse.

Testing For Voltage

1. Connect one lead of a test light to a known good ground. If you are using a voltmeter, be sure it is the voltmeter's negative lead that you have

connected to ground.

2. Connect the other lead of the test lamp or voltmeter to a selected test point (connector or terminal).
3. If the test lamp glows, there is voltage present. If you are using a voltmeter, note the voltage reading. It should be within one volt of measured

battery voltage. A loss of more than one volt indicates a problem.

Diagram Information and Instructions|Page 432 > < Diagram Information and Instructions|Page 430