chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

A/C - Odor at Start up in Humid Climates|Page 10132 > < A/C - Odor at Start up in Humid Climates|Page 10130
Page 2
background image

Accumulator Mounting

Evaporator Hose To Accumulator

REMOVE OR DISCONNECT 

1. Negative battery cable. 
2. Recover refrigerant from the system.
3. Blower motor resistor harnes.
4. Electrical connectors, as necessary.
5. Evaporator tube from evaporator. 

Remove:
-

Evaporator tube clip screw.

-

Evaporator tube clip from accumulator.

-

Evaporator tube from evaporator.

  

6. Accumulator. 
7. Evaporator and blower module screws and nuts.
8. Evaporator and blower module from the vehicle.
9. Screws.

10. Case sections.
11. Core.

INSTALL OR CONNECT 

1. Core to case.

-

Add the same amount of PAG oil that was recovered during evacuation.

2. Case sections.
3. Screws.
4. Evaporator and blower assembly to the vehicle.
5. Evaporator and blower module screws and nuts. 

Tighten
-

Bolts and stud to 4.5 Nm (40 lbs. in.).