chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Recirculation Actuator|Page 15823 > < Recirculation Actuator|Page 15821
Page 9
background image

MODE ACTUATOR REPLACEMENT (WITHOUT D07)

REMOVAL PROCEDURE

1. Remove the floor air outlet duct extension (1) from the floor duct (2).

2. Disconnect the electrical connection at the mode actuator (10).

3. Remove the mode actuator mounting screws from the HVAC module.
4. Remove the mode actuator as an assembly with the actuator cam. 

INSTALLATION PROCEDURE

1. Install the mode actuator as an assembly with the actuator cam.

-

Line up the heater/defroster valve lever with the mode actuator cam slot.

-

Line up the A/C valve lever with the mode actuator cam.

2. Install the mode actuator mounting screw to the HVAC module.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the screw to 1.6 N.m (14 lb in).

Recirculation Actuator|Page 15823 > < Recirculation Actuator|Page 15821