chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

A/C - Blower Motor Inop. or Works On Low Speed Only|Page 16013 > < Campaign - HVAC Blower Not Functional Runs Continuously|Page 16007
Page 1
background image

Blower Motor Resistor: Customer Interest
A/C - Blower Motor Inop. or Works On Low Speed Only

Bulletin No.: 05-01-38-012C

Date: November 02, 2006

TECHNICAL

Subject:
EI05082 - Loss of Blower Motor Speeds Except for Low Speed or Inoperative (Replace Blower Motor Resistor and Resistor Module Connector)

Models:
2004-2006 Chevrolet Avalanche, Silverado, Suburban, Tahoe, TrailBlazer, TrailBlazer EXT
2007 Chevrolet Silverado (Classic) Built Prior to September 1, 2006
2004-2006 GMC Envoy, Envoy XL, Sierra, Yukon, Yukon Denali, Yukon XL
2007 GMC Sierra (Classic) Built Prior to September 1, 2006

with HVAC System AC Front, Manual Temp Control (RPO CJ3) or Heater Only (RPO C42)

Supercede:

This bulletin is being revised to clarify the Warranty Information. Please discard Corporate Bulletin Number 05-01-38-012B (Section 01 - HVAC).

Condition

Some customers may comment that the blower will only work on low speeds or has become inoperative.

Correction

REPLACE THE BLOWER MOTOR RESISTOR AND RESISTOR MODULE CONNECTOR.

Replace the blower motor resistor and module connector using the following procedure:

Remove the blower fuse.

Fullsize Trucks and Utility Vehicles - Htr A/C & HVAC 1 fuses

Midsize Utility Vehicles - Blower Fuse 35 located in the Underhood Fuse Block

Lower the hush panel or close-out panel enough to gain access to the resistor module connector.

Disconnect the connector from the resistor module.

Remove the tape from the wiring harness to expose the wiring.

A/C - Blower Motor Inop. or Works On Low Speed Only|Page 16013 > < Campaign - HVAC Blower Not Functional Runs Continuously|Page 16007