chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

HVAC Systems - Manual|Page 16626 > < HVAC Systems - Manual
Page 1
background image

Control Module HVAC: Service and Repair
HVAC Systems - Automatic

BLOWER MOTOR CONTROL PROCESSOR REPLACEMENT

REMOVAL PROCEDURE

1. If equipped, remove the sound insulator panel.
2. Disconnect the electrical connector at the blower motor.

3. Disconnect the electrical connector (4) from the blower motor control processor (2).
4. Remove the blower motor control processor retaining screws (3) from the HVAC module (1).
5. Remove the blower motor control processor (2) from the HVAC module (1).

INSTALLATION PROCEDURE

1. Install the blower motor control processor (2) to the HVAC module (1).
2. Install the blower motor control processor retaining screws.

Tighten the screws to 1.6 N.m (14 lb in).

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Connect the electrical connector (4) to the blower motor control processor (2).

HVAC Systems - Manual|Page 16626 > < HVAC Systems - Manual