1. If necessary, install the CVS to the CVS bracket.
2. Install the CVS to the vehicle. Ensure the locator tab is inserted into the frame hole.
3. Connect the CVS line to the canister.

NOTE:  Refer to Fastener Notice in Service Precautions.

4. Install the CVS bracket bolt.

Tighten the bolt to 12 N.m (106 lb in).

5. Connect the CVS electrical connector (1).
6. Lower the vehicle.