18. Connect the outlet duct to the ESB duct.
19. Install the ESB power cable.
20. Install the ESB fuse power cable.

Energy Storage Box (ESB) Fuse Holder Replacement

ENERGY STORAGE BOX (ESB) FUSE HOLDER REPLACEMENT (WITH RPO CODE HP2)

REMOVAL PROCEDURE

1. Remove the maxi-fuse.
2. Remove the fuse power cable from the fuse holder.
3. Remove the service disconnect power cable from the fuse holder.
4. Remove the fuse holder screws.
5. Remove the fuse holder.

INSTALLATION PROCEDURE

1. Install the fuse holder.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the fuse holder screws.

Tighten
Tighten the screws to 2 N.m (18 lb in).

3. Install the service disconnect power cable to the fuse holder.
4. Install the fuse power cable to the fuse holder.
5. Install the maxi-fuse.

Energy Storage Box (ESB) Fuse Power Cable Replacement

ENERGY STORAGE BOX (ESB) FUSE POWER CABLE REPLACEMENT (WITH RPO CODE HP2)

REMOVAL PROCEDURE

How to Disable Electrical System|Page 3106 > < How to Disable Electrical System|Page 3104