chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

How to Disable Electrical System|Page 3122 > < How to Disable Electrical System|Page 3120
Page 63
background image

1. Install the high current sensor carrier.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the high current sensor carrier nut.

Tighten
Tighten the nut to 10 N.m (89 lb in).

3. Install the high current sensor

Energy Storage Box (ESB) Service Disconnect Power Cable Replacement

ENERGY STORAGE BOX (ESB) SERVICE DISCONNECT POWER CABLE REPLACEMENT (WITH RPO CODE HP2)

REMOVAL PROCEDURE

1. Remove the energy storage box (ESB) intermediate cover.
2. Remove the service disconnect power cable nuts (1) from the high current connector (HCC) and the service disconnect switch.
3. Remove the service disconnect power cable (2) from the HCC and service disconnect switch.

INSTALLATION PROCEDURE

IMPORTANT:  Ensure that the power cable is installed to the negative side of the HCC.

How to Disable Electrical System|Page 3122 > < How to Disable Electrical System|Page 3120