chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Water Pump|Specifications|Page 4196 > < Water Pump|Specifications|Page 4194
Page 3
background image

Important:  All gaskets surfaces are to be free of oil or other foreign material during assembly.

1. Install the water pump and NEW gaskets.

Notice:  Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners
requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use
paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint
clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid
damage to parts and systems.

2. Install the water pump bolts.

1. Tighten the bolts a first pass to 15 Nm (11 ft. lbs.).
2. Tighten the bolts a final pass to 30 Nm (22 ft. lbs.).

3. Install the heater inlet hose to the water pump.
4. Position the heater inlet hose clamp at the water pump.

5. Install the surge tank outlet hose to the water pump.
6. Position the surge tank outlet hose clamp at the water pump.

Water Pump|Specifications|Page 4196 > < Water Pump|Specifications|Page 4194