chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Recirculation Actuator|Page 15704 > < Recirculation Actuator|Page 15702
Page 10
background image

3. Connect the electrical connection at the mode actuator (10).

4. Install the floor air outlet duct extension (1) to the floor air duct (2).

Mode Actuator (With RPO Code D07)

MODE ACTUATOR REPLACEMENT (WITH D07)

REMOVAL PROCEDURE

1. Remove the floor air outlet duct extension (1) from the floor duct (2).
2. Remove the center console.
3. Remove the screws from the center console duct.
4. Remove the center console duct.

5. Disconnect the electrical connection from the mode actuator (10).

Recirculation Actuator|Page 15704 > < Recirculation Actuator|Page 15702