chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Drive Motor Generator Control Module Sight Shield Replacement|Page 4641 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 4639
Page 7
background image

6. Install the sight shield circuit breaker (2) and secure with bolts (1). Tighten the bolts to 5 Nm (44 lb in) .

7. Connect the APM assembly connectors (1 and 3) and install any removed locking tabs.
8. Connect the APM assembly connector (2) using the following procedure:

1. Push the lever up.

Note

Install the connector (2) without disturbing the position of the lever. DO NOT use the lever to install the connector in place.

2. Install the connector (2) onto the terminals by pushing on the connector only.
3. Rotate the lever after the terminals are engaged.
4. Push the green tab to lock the lever.

Drive Motor Generator Control Module Sight Shield Replacement|Page 4641 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 4639