9. Remove the caps (3, 6) from the drive motor generator power inverter coolant pipes.

10. Connect the drive motor generator power inverter module (PIM) cooling inlet and outlet hoses (4, 5).
11. Install the shield circuit harness (1) and terminal fastener (2). Tighten the terminal fastener to 9 Nm (80 lb in) .

12. Install the PIM 3 phase cables (3, 5) into the PIM distribution box with new seals (6).
13. Install the PIM 3 phase cable mounting fasteners (2, 4). Tighten the mounting fastener to 9 Nm (80 lb in) .

Caution:  Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit
board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

14. Install the PIM 3 phase cable terminal fasteners (1). Tighten the terminal fastener to 9 Nm (80 lb in) .