chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Drive Motor Generator Control Module Sight Shield Replacement|Page 4633 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 4631
Page 2
background image

Caution:  Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit
board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

5. Remove the drive motor generator power inverter control module (PIM) 3 phase cable terminal fasteners (1).

Caution:  High Voltage (HV) cables should never be removed from the mounting block. Removal of the individual HV cable from the mounting
block may result in HV cable and/or component damage from improper:

*

Cable sealing

*

Electrical shielding

*

Terminal position assurance

6. Remove the PIM 3 phase cable mounting fasteners (2, 4).
7. Remove the PIM 3 phase cables (3, 5) from the PIM distribution box.
8. Remove and discard the seals (6).

Drive Motor Generator Control Module Sight Shield Replacement|Page 4633 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 4631