chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

175 Amp Mega Fuse Replacement (With Auxiliary Battery)|Page 12513 > < 175 Amp Mega Fuse Replacement (With Auxiliary Battery)|Page 12511
Page 8
background image

5. Install the starter solenoid cable terminal (2) to the fuse stud.
6. Install the starter solenoid cable nut (1) to the fuse stud.

Tighten the nut to 15 Nm (11 lb ft).

7. Install the fuse cover.
8. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (With Single Battery)   (See: Battery/Battery

Cable/Service and Repair)Battery Negative Cable Disconnection and Connection (With Auxiliary Battery)   (See: Battery/Battery Cable/Service
and Repair)Battery Negative Cable Disconnection and Connection (With Dual Batteries)   (See: Battery/Battery Cable/Service and Repair) .

200 Amp Mega Fuse and Auxiliary Electrical Center 12VDC Junction Block Replacement

200 Amp Mega Fuse and Auxiliary Electrical Center 12VDC Junction Block Replacement