chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Symptoms - Seat Heating and Cooling|Page 16588 > < Symptoms - Seat Heating and Cooling|Page 16586
Page 6
background image

16. If all circuits test normal, test or replace the appropriate seat cushion or seat back ventilation heating and cooling module.

Component Testing

Heated and Cooled Seat Switch

1. Ignition OFF, disconnect the X4 harness connector at the appropriate door lock/window switch.
2. Test for infinite resistance between the low reference circuit terminal 4 and the signal terminals listed below the with the switch in the open

position.

*

Seat back only mode switch terminal 7

*

Seat back cushion heat switch terminal 6

*

Seat cool switch terminal 3

‹› If not the specified value, replace the heated and cooled seat switch.

3. Test for less than 2 Ohms  between the low reference circuit terminal 4 and the signal terminals listed below with the appropriate switch in the

closed position.

*

Seat back only mode switch terminal 7

*

Seat back cushion heat switch terminal 6

*

Seat cool switch terminal 3

‹› If greater than the specified range, replace the heated and cooled seat switch.

4. Connect a 3 A fused jumper wire between the low reference circuit terminal 4 and ground.
5. Connect a test lamp between B+ and each control terminal listed below. The appropriate indicator should illuminate.

*

Seat back only mode indicator terminal 11

*

Seat cool mode indicator terminal 12

*

Seat back and cushion indicator terminal 10

*

Low temperature indicator terminal 9

*

Medium temperature indicator terminal 1

*

High temperature indicator terminal 2

‹› If any indicator does not illuminate, replace the heated and cooled seat switch.

Ventilation Heat and Cool Module

1. Ignition OFF, disconnect the harness connectors at the seat cushion and seat back ventilation heat and cool modules.

Note:  If the resistance is measured with the seat still warm or cool, the resistance values will vary. At 68°F (20°C), the nominal resistance value is
1200 Ohms  ±5 percent. For warmer or cooler ambient temperatures, refer to the Temperature vs Resistance table below. The delta resistance
values between the seat cushion and seat back temperature sensors should not be greater than 2000 Ohms.

2. Test for 300 Ohms  - 18 kOhms  between the temperature sensor signal circuit terminal 5 and the low reference circuit terminal 8.

‹› If not within the specified range, replace the ventilation heat and cool module.

Note:  The test leads must be connected in the correct polarity, otherwise lower out of range values will appear. Use the Positive Lead for the
COOL control circuit and the Negative Lead for the HEAT control circuit. If the resistance is measured with the seat still warm or cool, the
resistance values will vary even if the system was powered up for just a few seconds. The TED must be allowed to stabilize to room temperature
prior to a measurement. The conditions listed below will change the resistance to out of range values:

*

The test leads are incorrectly connected.

*

Air blowing across the TED

*

Measuring the resistance at other than room temperature of 70°F

*

Holding the TED portion of the heated and cool ventilation module in your hand

In warmer or cooler climates where room temperature conditions of 70°F (21°C) may be unattainable, resistance values may read above the
specified range. Use a heat gun or a blower to warm or cool the TED while measuring the resistance. The resistance values should slowly lower
toward the specified range.

3. Test for 0.9 - 10 Ohms  between the heat control circuit terminal 1 and the cool control circuit terminal 3.

‹› If not within the specified range, replace the ventilation heat and cool module.