3. Disconnect the negative battery cables.  
4. Remove the air cleaner outlet duct. 

5. Important:  Do not use a screwdriver or other tool to pry the hose loose. The hose can be torn or damage. Loosen the hose by twisting.

Loosen the charged air cooler outlet duct to intake hose clamp.

6. Remove the charged air cooler duct from the intake.
7. Remove the generator mounting bracket.
8. Remove the Exhaust Gas Recirculation (EGR) cooler tube. 

9. Disconnect the fuel injection control module electrical connectors.

10. Remove the upper fuel injection control module fuel line bolt.
11. Remove and discard the washer from the banjo fitting.

Exhaust Gas Recirculation (EGR) Coolant Hoses/Pipes Replacement|Page 3762 > < Exhaust Gas Recirculation (EGR) Coolant Hoses/Pipes Replacement|Page 3760