Silverado 3500 2WD V8-6.6L DSL Turbo (2006)
4. Install the generator cable to the generator, perform the following:
1. Install the generator cable to the stud.
2. Install the generator cable nut.
Tighten the nut to 9 N.m (80 lb in).
3. Position the boot to cover the stud.
5. If necessary, install the engine sight shield.
6. Connect the negative battery cable.
Generator Bracket Replacement
GENERATOR BRACKET REPLACEMENT
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable.
2. Remove the air cleaner.
3. Remove the drive belt.
4. Remove the upper fan shroud.
5. Remove the electrical harness clip bolts.