background image

Air Door Actuator / Motor: Description and Operation

HVAC CONTROL MODULE

Mode Actuator
The mode actuator is a 5-wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference, control, 
5-volt reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 or 5-volt signal to command the
actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal commands the actuator movement in
opposite directions. When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position signal between 0.5 volts.

The HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count
range. When the module sets a commanded, or targeted value, the control signal is changed to either 0 or 5 volts depending upon the direction that the
actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the
position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

AIR DISTRIBUTION

Mode Actuator
The mode actuator is an electronic stepper motor with feedback potentiometers. The HVAC control module sends different signals to the mode door
actuator through the mode door control circuit. Zero volts drives the actuator in one direction while 5 volts moves the actuator in the opposite
direction. When the actuator receives 2.5 volts, the actuator rotation stops. A 5-volt reference signal is sent out over the 5-volt reference circuit to the
mode actuator. When you select a desired mode setting, logic determines the value of the mode actuator signals. The HVAC control module's software
uses this reference voltage in order to determine the position of the mode actuator through the mode door position signal circuit. The motor moves the
mode door to the desired position.

AIR TEMPERATURE ACTUATOR

The air temperature actuators are a 5-wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference,
control, 5-volt reference, and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5, or 5-volt signal to
command the actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal commands the
actuator movement in opposite directions. When the actuator shaft rotates, the potentiometers adjustable contact changes the door position signal
between 0.5 volts.

The HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count
range. When the module sets a commanded, or targeted, value, the control signal is changed to either 0 or 5 volts depending upon the direction that
the actuator needs to rotate to reach the commanded value. As the actuator shaft rotates, the changing position signal is sent to the module. Once the
position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

RECIRCULATION ACTUATOR

The HVAC control module controls the air intake through the recirculation actuator. Recirculation is not available when the mode is in defrost. When
the mode is in defog, Recirculation will only be available for 10 minutes. The operator must activate the blower for Recirculation operation. The A/C
high-pressure recirculation switch can cause the HVAC system to recirculate air. If the recirculation switch is pressed into the ON position when the
mode switch is in an unavailable mode position, then the recirculation switch LED will flash 3 times. When the high side pressure reaches 2206-2620
kPa (320-380 psi)
, the PCM will place the HVAC system in recirculation mode. The high side pressure is lowered when the inside air cools the 
refrigerant within the A/C evaporator. When the high-side pressure reaches 1447-1861 kPa (210-270 psi), the PCM will place the HVAC system out
of recirculation mode.