chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Actuator Recalibration - HVAC|Page 10477 > < Actuator Recalibration - HVAC|Page 10475
Page 11
background image

3. Connect the electrical connector to the recirculation actuator (1).
4. Install the air distribution duct.

Recirculation Actuator (Visteon)

RECIRCULATION ACTUATOR REPLACEMENT (VISTEON)

REMOVAL PROCEDURE

1. Remove the HVAC module assembly.

2. Remove the screws from the evaporator core cover (1).
3. Remove the evaporator core cover (1) from the HVAC module assembly (2).

4. Remove the screws from the recirculation actuator (1).
5. Remove the recirculation actuator (1) from the HVAC module assembly (2).

Actuator Recalibration - HVAC|Page 10477 > < Actuator Recalibration - HVAC|Page 10475