Air Cleaner Fresh Air Duct/Hose: Service and Repair

AIR CLEANER OUTLET DUCT REPLACEMENT

REMOVAL PROCEDURE

1. Loosen the outlet duct clamps at the turbocharger and the mass air flow (MAF)/intake air temperature (IAT) sensor.
2. Remove the air cleaner outlet duct.

INSTALLATION PROCEDURE

IMPORTANT:  The air cleaner outlet duct must be fully seated against the positive stop feature on the turbocharger inlet.

1. Install the air cleaner outlet duct.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Tighten the outlet duct clamps at the turbocharger and the MAF/IAT sensor.

Tighten
Tighten the clamps to 6 N.m (53 lb in).