3. Remove the screws from the right air temperature actuator (3).
4. Remove the right air temperature actuator (3) from the HVAC module assembly (2).
INSTALLATION PROCEDURE
1. Install the right air temperature actuator (3) from the HVAC module assembly (2).
2. Install the screws to the right air temperature actuator (3).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 2 N.m (18 lb in).
3. Connect the electrical connector to the right air temperature actuator.
4. Install the I/P carrier.
5. Reprogram the air temperature actuator. Refer to Re-Calibrating Actuators.
Mode Actuator (With RPO Code D07)
MODE ACTUATOR REPLACEMENT (WITH RPO CODE D07)
REMOVAL PROCEDURE
1. Remove the floor air outlet duct extension (1) from the floor duct (2).
2. Remove the center console.
3. Remove the screws from the center console duct.
4. Remove the center console duct.
5. Disconnect the electrical connection from the mode actuator (10).