chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Housing Assembly HVAC > < Discharge Hose Replacement (LB7)|Page 17016
Page 2
background image

2.  Install the suction hose to the accumulator.

Notice:  Refer to Fastener Notice.

3.  Install the NEW suction hose nut to the accumulator.

Tighten the nut to 16 N.m (12 lb ft).

4.  Install the suction hose to the compressor (1).
5.  Install the NEW suction hose mounting bolt (3).

Tighten the bolt to 16 N.m (12 lb ft).

6.  Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.  See: Service and Repair/Removal and

Replacement/Refrigerant Recovery and Recharging

7.  Leak test the fittings of the component using the J 39400-A.

Housing Assembly HVAC > < Discharge Hose Replacement (LB7)|Page 17016