Silverado Classic 2500 2WD V8-6.0L (2007)
Air Duct: Service and Repair
Floor Air Outlet Duct Replacement - Right Side
Floor Air Outlet Duct Replacement - Right Side
Removal Procedure
1. Remove the right closeout/insulator panel.
2. Remove the screw from the right floor air outlet duct (3).
3. Remove the right floor air outlet duct (3) from the HVAC module (2).
Installation Procedure
1. Install the right floor air outlet duct (3) to the HVAC module (2).
Notice: Refer to Fastener Notice.
2. Install the screw to the right floor air outlet duct (3).
Tighten the screw to 1.6 N.m (14 lb in).
3. Install the right closeout/insulator panel.