chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Thermostat Bypass Pipes Replacement|Page 5645 > < Thermostat Bypass Pipes Replacement|Page 5643
Page 5
background image

33. Remove the thermostat housing bolts and nuts.
34. Remove the thermostat housing, with the bypass pipe.
35. Remove and discard the thermostat bypass pipe to water pump O-ring seal.
36. Remove and discard the thermostat housing gaskets.
37. If necessary, perform the following steps:

1. Remove the thermostat bypass pipe from the thermostat housing.
2. Remove and discard the thermostat bypass pipe O-ring seal.
3. Remove the thermostat cover bolts and cover.
4. Remove the thermostats.
5. Remove and discard the thermostat seals.

38. If required, clean and inspect the thermostat housing. Refer to Engine Coolant Thermostat Housing Cleaning and Inspection.

Installation Procedure

1. If necessary, perform the following steps:

1. Install NEW seals to the thermostats.
2. Install the thermostats.

3. Notice:  Refer to Fastener Notice in Service Precautions.

Install the thermostat cover and bolts.
Tighten the bolts to 21 Nm (15 ft. lbs.).

4. Install a NEW O-ring seal to the thermostat bypass pipe.
5. Install the thermostat bypass pipe to the thermostat housing.

2. Install a NEW thermostat bypass pipe to water pump O-ring seal.
3. Install the thermostat housing using NEW gaskets.
4. Install the thermostat housing bolts and nuts

Tighten the bolts/nuts to 21 Nm (15 ft. lbs.).

Thermostat Bypass Pipes Replacement|Page 5645 > < Thermostat Bypass Pipes Replacement|Page 5643