47. Install the 4 electrical connectors to the hydraulic pump solenoids as follows.
-
Connector C 4 Green, to solenoid valve 4 (with Red and Green CKT).
-
Connector C 3 Orange, to solenoid 3 (with a LT Blue CKT.)
-
Solenoid Valve 2.
-
Connector C 1 Green to solenoid valve 1 (with WHITE CKT).
-
Connector C 2 Blue to solenoid valve 2. (with Dark BLUE CKT).
-
Folding Top Pump with Motor (6).
48. Remove the protective covering.
49. Connect the battery.
50. Close the stowage compartment lid.
51. Bleed the hydraulic system. Refer to Folding Top Hydraulic System Bleeding Procedure.
52. Inspect the hydraulic system for fluid leaks.
53. Inspect the hydraulic system fluid level and add fluid as needed.
54. Inspect the folding top for proper operation.