1. Install the recirculation actuator (1) to the HVAC module assembly (2).
2. Install the screws to the recirculation actuator (1).

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the screws to 2 N.m (18 lb in).

3. Install the evaporator core cover (1) to the HVAC module assembly (2).

4. Install the screws to the evaporator core cover (1).

Tighten the screws to 2 N.m (18 lb in).

5. Install the HVAC module assembly.
6. Reprogram the recirculation actuator. Refer to Re-Calibrating Actuators,  See: Testing and Inspection/Programming and Relearning/Actuator

Recalibration - HVAC

Air Duct > < HVAC System - Automatic|Page 9479