chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 509 > < Diagram Information and Instructions|Page 507
Page 16
background image

9. Use a small flat-bladed tool to gently lift the terminal retaining tab while gently pulling the wire out of the back of the Connector. Always

remember never use force when pulling a terminal out of a Connector. If the terminal is severely bent or damaged, push the wire out of the front of
the Connector instead of pulling it through. This will prevent damage to the internal seals of the Connector. Once the terminal is pushed out of the
Connector, cut the wire as close to the terminal as possible and pull the wire through the Connector.

TERMINAL REPAIR PROCEDURE

Use the appropriate wire assembly kit available through Saturn Service Parts.
1. Slide the new terminal into the correct cavity at the back of the Connector.
2. Push the terminal into the Connector until it locks into place. The new terminal should be even with the other terminals. Insure that the terminal is

locked in place by gently pulling on the wire.

3. Replace the nose piece.
4. Replace the dress cover.

Circuit Protection - Circuit Breakers

CIRCUIT PROTECTION - CIRCUIT BREAKERS

A circuit breaker is a protective device that is designed to open the circuit when a current load is in excess of the rated breaker capacity. If there is a short
or other type of overload condition in the circuit, the excessive current will open the circuit between the circuit breaker terminals. Two types of circuit
breakers are used.

Circuit Breaker: This type opens when excessive current passes through it for a period of time. It closes again after a few seconds, and if the cause of
the high current is still present, it will open again. The circuit breaker will continue to cycle open and closed until the condition causing the high current
is removed.

Positive Temperature Coefficient (PTC) Circuit Breaker: This type greatly increases its resistance when excessive current passes through it. The
excessive current heats the PTC device, as the device heats its resistance increases. Eventually the resistance gets so high that the circuit is effectively
open. Unlike the ordinary circuit breaker the PTC unit will not reset until the circuit is opened, by removing the Voltage from its terminals. Once the
Voltage is removed the circuit breaker will re-close within a second or 2.

Circuit Protection - Fuses

CIRCUIT PROTECTION - FUSES

Diagram Information and Instructions|Page 509 > < Diagram Information and Instructions|Page 507