Control Module HVAC: Description and Operation
HVAC Systems - Automatic

HVAC CONTROL COMPONENTS

HVAC Control Module

The HVAC control module is a class 2 device that interfaces between the operator and the HVAC system to maintain air temperature and distribution
settings. The battery positive voltage circuit provides power that the control module uses for keep alive memory (KAM). If the battery positive voltage
circuit loses power, all HVAC DTCs and settings will be erased from KAM. The body control module (BCM), which is the vehicle mode master,
provides a device on signal. The control module supports the features as in table.

Auxiliary HVAC Control Module
The auxiliary HVAC control module is a class 2 device that receives analog inputs from the front HVAC control assembly and class 2 message inputs
from the rear seat audio (RSA) control module to maintain auxiliary air temperature and auxiliary air distribution settings. The battery positive voltage
circuit provides power that the control module uses for keep alive memory (KAM). If the battery positive voltage circuit loses power, all auxiliary
HVAC DTCs and settings will be erased from KAM. The auxiliary HVAC control module will perform a recalibration of the electric actuators when
commanded with a scan tool or if KAM is lost. This will ensure the actuators are moving with in the calibrated range.

RSA Control Module
The RSA Control Module is a class 2 device that interfaces between the rear seat passengers and the auxiliary HVAC control module. The battery
positive voltage circuit provides power that the control module uses for keep alive memory (KAM). Air temperature, blower motor and air delivery
rocker type switches are located on the face of the module. These switches enable the module to send a class 2 serial data message to the auxiliary
HVAC control module for the change request. The module does not store auxiliary HVAC DTCs.

Front Auxiliary HVAC Control Assembly
The front auxiliary HVAC control assembly is a non-class 2 device that interfaces between the front seat occupants and the auxiliary HVAC control
module. A 5-volt reference is supplied to the control assembly by the auxiliary HVAC control module. The control assembly varies the 5-volt
reference through three integrated potentiometers to control mode, air temperature door position, and blower motor speed inputs to the auxiliary
HVAC control module.

Blower Motor Control Processor
The blower motor control processor controls the speed of the blower motor by increasing or decreasing the voltage drop on the ground side of the
blower motor. The HVAC control module provides a low side pulse width modulated signal to the blower motor control processor over the blower
motor speed control circuit. As the requested blower speed increases, the HVAC control module increases the amount of time that the speed signal is
modulated to ground. As the requested blower speed decreases, the HVAC control module decreases the amount of time that the signal is modulated
to ground.

Auxiliary Blower Motor Control Processor
The auxiliary blower motor control processor controls the speed of the blower motor by increasing or decreasing the voltage drop on the ground side
of the auxiliary blower motor. The auxiliary HVAC control module provides a low side pulse width modulated signal to the auxiliary blower motor
control processor over the auxiliary blower motor speed control circuit. As the requested blower speed increases, the auxiliary HVAC control module
increases the amount of time that the speed signal is modulated to ground. As the requested blower speed decreases, the auxiliary HVAC control
module decreases the amount of time that the signal is modulated to ground.

AIR DISTRIBUTION

Mode Actuator
The mode actuator is an electronic stepper motor with feedback potentiometers. The HVAC control module sends signals to the mode door actuator
through the mode door control circuit. Zero volts drive the actuator in one direction while 5-volts move the actuator in the opposite direction. When
the actuator receives 2.5-volts, the actuator rotation stops. A 5-volt reference signal is sent out over the 5-volt reference circuit to the mode actuator.
When you select a desired mode setting, logic determines the value of the mode actuator signals. The HVAC control module's software uses this
reference voltage in order to determine the position of the mode actuator through the mode door position signal circuit. The motor moves the mode
door to the desired position.