Steps 14-15

Temperature Displays SC or OC - Mirrors

MIRRORS - TEMPERATURE DISPLAYS SC OR OC

Ambient Air Temperature Sensor Resistence

The table will be used to measure the resistance of the sensor and compare it with the actual ambient temperature. The mirror's temperature accuracy
should be within 5 degrees of the actual temperature. The actual temperature should not be taken from a radio station, a sign displaying the temperature,
etc. A temperature measuring tool such as a thermometer should be used. Some temperature measuring tools may be within 5 degrees of the actual
temperature. Make sure to consult the manufacturer for the accuracy of the tool. This comparison can make the mirror seem off by 5-10 degrees of the
actual temperature when it is not.