1. Install the mode actuator as an assembly with the actuator cam.

-

Line up the heater/defroster valve lever with the mode actuator cam slot.

-

Line up the A/C valve lever with the mode actuator cam.

2. Install the mode actuator mounting screw to the HVAC module.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the screw to 1.6 N.m (14 lb in).

3. Connect the electrical connection at the mode actuator (10).

4. Install the floor air outlet duct extension (1) to the floor air duct (2).

Mode Actuator (With RPO Code D07)

MODE ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the floor air outlet duct extension (1) from the floor duct (2).
2. Remove the center console.
3. Remove the screws from the center console duct.
4. Remove the center console duct.