Blower Motor: All Technical Service Bulletins
A/C - Whistle Noise/Blower Motor Stalls/Vibrates

Bulletin No.: 06-01-39-011A

Date: March 22, 2007

TECHNICAL

Subject:
HVAC Whistle Noise/Blower Motor Stalls or Vibrates (Reattach Adhesive Foam to Recirculation Door/Air Inlet Valve)

Models:
2006 Cadillac Escalade Models
2006 Chevrolet Avalanche, Suburban, Tahoe
2006-2007 Chevrolet Silverado (Classic)
2006 GMC Yukon Model
2006-2007 GMC Sierra (Classic)

with Delphi Built HVAC Cases Only

Attention:

This bulletin only applies to Delphi-built HVAC cases, which can be easily identified by visually inspecting the HVAC case from under the
passenger instrument panel. The Visteon case is bolted together at the case halves and the bolts are silver in color. The Delphi case will be heat
staked together at the HVAC case halves. If prior work has been performed on the Delphi case, the procedure is to bolt the case back together, so you
may find bolts of many different colors. If there is any question, check the repair history and drop down the HVAC sound insulator panel to inspect
the blower motor assembly. The Visteon blower motor will be bolted into the case. The Delphi blower motor turns inside the case and will have a
plastic lock tab on the motor.

Supercede:

This bulletin is being revised to update the statement above regarding how to identify a Delphi or Visteon HVAC case. Please discard Corporate Bulletin
Number 06-01-39-011 (Section 01 - HVAC).

Condition

Some customers may comment on a whistle sound when the blower motor is on and the heating, ventilation and air conditioning (HVAC) control is put
into recirculation mode. Other customers may comment that the blower motor stalls out or vibrates or that a "sticky" noise is present during air
recirculation door operation.

Cause

The adhesive foam used on the air recirculation door (air inlet valve) may not be properly secured, causing some of the foam to contact other HVAC
components. The foam could potentially come in contact with the blower motor fan and/or the foam may stick to the inner HVAC case walls, causing the
door to stick or hang up.

Correction

Locate the loose foam and reattach the adhesive foam to the recirculation door using the steps below:

Remove two screws from the right side HVAC sound insulator panel (hush panel).

Drop down the insulator panel.

Disconnect the electrical connector from the blower motor.

A/C - Whistle Noise/Blower Motor Stalls/Vibrates|Page 14099 > < A/C - Blower Motor Inoperative or Won't Shut OFF|Page 14094