14. Tighten the CMP actuator solenoid valve.

1. Tighten the bolt a first pass to 65 N.m (48 lb ft).
2. Tighten the bolt a final pass an additional 90 degrees using J 45059.

15. Remove the J 42386-A (1) and bolts.
16. Install the starter motor. 
17. Install the oil pump. Refer to Oil Pump, Screen, and Crankshaft Oil Deflector Replacement.

Timing Chain Tensioner > < Timing Chain|Service and Repair|Page 5092