chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

All Technical Service Bulletins for Refrigerant:|922501A > < A/C - Growl/Pumping Noise, Check Refrigerant Level
Page 1
background image

Refrigerant: All Technical Service Bulletins
A/C - Growl Noise During Operation

Number: 93-219-1A
Section: 1A
Date: MAY 1993
Corporate Bulletin No.: 361202
ASE No.: A7

Subject:
GROWL NOISE DURING AIR CONDITIONING OPERATION

Model and Year:
1992-93 SUBURBAN WITH REAR AIR CONDITIONING (RPO C69)

CONDITION:
Owners of some 1992 and 1993 Suburbans with C69 (rear air conditioning) may comment on a noise (growl/pumping) during A/C operation (usually at
idle and above engine speeds).

CAUSE:
Low charge due to leaks, improper initial charge, or system sensitivity to amount of charge.

CORRECTION:
1.

Thoroughly check A/C system for refrigerant leaks.

2.

Repair any and all leaks found.

3.

Evacuate/purge the system of its refrigerant charge.

4.

Recharge the system with 4-1/2 lbs (72 oz.) of refrigerant (vehicle label says 4-1/4 lbs (68 oz.)

IMPORTANT:

Do not assume the vehicle has a full charge of 68 oz. and add 4 oz. Fully evacuate the system and recharge with 72 oz. of R12.

Specific instructions on evacuation and charge can be found in Section 1B of Light Duty Truck service manual.

WARRANTY INFORMATION:  
For vehicles repaired under warranty, use:

LABOR OPERATION:  T7631
LABOR TIME:  1.0 hr.

Labor operation includes leak check, evacuation, and recharge. Consult the Labor Time Guide for the appropriate labor operation if leak repairs were
necessary.

All Technical Service Bulletins for Refrigerant:|922501A > < A/C - Growl/Pumping Noise, Check Refrigerant Level