chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

All Technical Service Bulletins: > < Cruise Control Module|Locations
Page 1
background image

Blower Motor Relay: Customer Interest
A/C - Blower Motor Runs After Vehicle Is Shut OFF

TECHNICAL

Bulletin No.: 03-01-38-015A

Date: October 27, 2008

Subject: 
HVAC Blower Motor May Run Continuously After Vehicle is Turned Off (Replace Blower Resistor Relay)

Models:
2004 Chevrolet Avalanche, Silverado, Suburban, Tahoe, TrailBlazer, TrailBlazer EXT
2004 GMC Envoy, Envoy XL, Sierra, Yukon, Yukon XL

with Manual Control HVAC (RPO CJ3)

Built Prior to August, 2003

Supercede:

This bulletin is being revised to update the parts information. Please discard Corporate Bulletin Number 03-01-38-015 (Section 01 - HVAC).

Condition

Some customers may comment on the HVAC blower motor running after the vehicle has been turned off. The blower may run for just a few minutes or
continuously until the battery is discharged.

Cause

A new style HVAC blower relay/resistor may stick in the "on" position. When the HVAC fan blower relay has been energized, the contacts may
"micro-weld" together. After this occurrence, the HVAC blower may not respond to the HVAC controller commands.

Correction

Replace the HVAC blower resistor/relay with the type used previous to the 2004 model year. The appropriate part numbers are listed in the table below.
For specific repair procedures, refer to the 2004 Service Information (SI) under Blower Motor Resistor Assembly Replacement (SI Document ID #
526350 (C/K) or # 729996 (S/T).

Parts Information

Warranty Information

Disclaimer

All Technical Service Bulletins: > < Cruise Control Module|Locations