chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Hybrid Controls|Page 7481 > < Hybrid Controls|Page 7479
Page 4
background image

3. Remove the drive motor generator power inverter control module (PIM) 3 phase cable terminal fasteners (1).
4. Remove the PIM 3 phase cable mounting fasteners (2, 4).
5. Remove the PIM 3 phase cables (3, 5) from the PIM distribution box.
6. Remove and discard the seals (6).

Caution:  Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic
circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

7. Remove the HV dc electric air conditioning compressor module (ACCM) cable terminal fasteners (1).
8. Remove the HV dc electric ACCM cable mounting fasteners (3).
9. Remove the HV dc electric ACCM cable (4) from the PIM distribution box.

10. Remove the HV dc battery cable terminal fasteners (2).
11. Remove the HV dc battery cable mounting fasteners (5).
12. Remove the HV dc battery cable (6) from the PIM distribution box.
13. Remove and discard the seals (7).

Hybrid Controls|Page 7481 > < Hybrid Controls|Page 7479