chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Automatic Control|Page 8250 > < Automatic Control|Page 8248
Page 8
background image

NOTE: Refer to Fastener Notice in Service Precautions. 

See: Service Precautions/Vehicle Damage Warnings

Tighten
Tighten the screws to 1.9 N.m (17 lb in).

4. Install the air outlet duct to the console.
5. Install the screw to the air outlet duct.

Tighten
Tighten the screw to 1.9 N.m (17 lb in).

6. Install the console. 

Recirculation Actuator

RECIRCULATION ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the HVAC module assembly.
2. Remove the air inlet assembly screws.

3. Remove the air inlet assembly.
4. Remove the recirculation actuator screws.
5. Remove the electrical connector from the recirculation actuator.
6. Remove the recirculation actuator.

INSTALLATION PROCEDURE

1. Install the recirculation actuator.
2. Install the screws to the recirculation actuator.

NOTE: Refer to Fastener Notice in Service Precautions. 

Automatic Control|Page 8250 > < Automatic Control|Page 8248