TERMINAL REPAIR PROCEDURE

Use the appropriate terminal and follow the instructions in the J-38125 

Circuit Protection - Circuit Breakers

CIRCUIT PROTECTION - CIRCUIT BREAKERS

A circuit breaker is a protective device that is designed to open the circuit when a current load is in excess of the rated breaker capacity. If there is a short
or other type of overload condition in the circuit, the excessive current will open the circuit between the circuit breaker terminals. Two types of circuit
breakers are used.

Circuit Breaker
This type opens when excessive current passes through it for a period of time. It closes again after a few seconds, and if the cause of the high current is
still present, it will open again. The circuit breaker will continue to cycle open and closed until the condition causing the high current is removed.

Positive Temperature Coefficient (PTC) Circuit Breaker
This type greatly increases its resistance when excessive current passes through it. The excessive current heats the PTC device, as the device heats its
resistance increases. Eventually the resistance gets so high that the circuit is effectively open. Unlike the ordinary circuit breaker the PTC unit will not
reset until the circuit is opened, by removing the voltage from its terminals. Once the voltage is removed the circuit breaker will re-close within a
second or 2.

Circuit Protection - Fuses

CIRCUIT PROTECTION - FUSES

The fuse is the most common method of an automotive wiring circuit protection. Whenever there is an excessive amount of current flowing through a
circuit the fusible element will melt and create an open or incomplete circuit. Fuses are an one time protection device and must be replaced each time
the circuit is overloaded. To determine if a fuse is open, remove the suspected fuse and examine the element in the fuse for an open (2). If not broken
(1), also check for continuity using a DMM or a continuity tester. If the element is open or continuity is suspect, replace the fuse with one of equal
current rating.

Circuit Protection - Fusible Links

Diagram Information and Instructions|Page 4411 > < Diagram Information and Instructions|Page 4409