background image

Shift Cable: Adjustments

Automatic Transmission Range Selector Cable Adjustment 

Adjustment Procedure 

1. Ensure that the range selector cable is not restricted.
2. Ensure that the floor shift control is in the PARK position.
3. Raise the vehicle. Refer to Vehicle Lifting.
4. Disconnect the range selector cable (4) from the range selector lever ball stud (6).
5. Ensure that the range selector lever is in the mechanical PARK position. (Rotate the range selector lever fully clockwise).

6. Release the locking tab (2) and slide the secondary lock cover (1) to the side.

7. Carefully squeeze the locking tabs (1) together to disengage the primary lock.